Partial wind load in STAAD.Pro is applied through ā€œGroupsā€. By default, STAAD.Pro considers structures as enclosed. STAAD.Pro will calculate wind load on the nearest face of the structure blocking the wind or the entire exposed area. To apply partial wind load, we will have to create ā€œGroupsā€ selecting the group of entities where the wind load will be applied.

A screenshot of construction project management software displaying a 3D view of a building model, resource lists, task schedules, and properties panel with integrated STAAD.Pro analysis for partial wind load calculations.

The procedure of applying partial wind load

  • Create the group, selecting the group of entities where the wind load will be added.
  • Assign the wind load case to the group in the command file.